mirror of
https://github.com/XiaoMi/ha_xiaomi_home.git
synced 2025-04-04 00:35:33 +08:00
Merge branch 'XiaoMi:main' into main
This commit is contained in:
commit
db30e4d275
@ -1,4 +1,12 @@
|
|||||||
# CHANGELOG
|
# CHANGELOG
|
||||||
|
## v0.2.3
|
||||||
|
### Changed
|
||||||
|
- Specify the service name and the property name during the climate entity's on/off feature initialization. [#899](https://github.com/XiaoMi/ha_xiaomi_home/pull/899)
|
||||||
|
- Remove the useless total-battery property from `SPEC_PROP_TRANS_MAP`.
|
||||||
|
### Fixed
|
||||||
|
- Fix the hvac mode setting error when changing the preset mode of the ptc-bath-heater.
|
||||||
|
- Fix the ambiguous descriptions of yeelink.bhf_light.v10 ptc-bath-heater mode value-list.
|
||||||
|
- Fix the power consumption value of chuangmi.plug.212a01. [#910](https://github.com/XiaoMi/ha_xiaomi_home/pull/910)
|
||||||
|
|
||||||
## v0.2.2
|
## v0.2.2
|
||||||
This version has modified the conversion rules of the climate entity, which will have effect on the devices with the ptc-bath-heater, the air-conditioner and the air-fresh service. After updating, you need to restart Home Assistant and check `xiaomi_home > CONFIGURE >
|
This version has modified the conversion rules of the climate entity, which will have effect on the devices with the ptc-bath-heater, the air-conditioner and the air-fresh service. After updating, you need to restart Home Assistant and check `xiaomi_home > CONFIGURE >
|
||||||
|
@ -51,6 +51,7 @@ from typing import Any, Optional
|
|||||||
|
|
||||||
from homeassistant.config_entries import ConfigEntry
|
from homeassistant.config_entries import ConfigEntry
|
||||||
from homeassistant.core import HomeAssistant
|
from homeassistant.core import HomeAssistant
|
||||||
|
from homeassistant.const import UnitOfTemperature
|
||||||
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
from homeassistant.helpers.entity_platform import AddEntitiesCallback
|
||||||
from homeassistant.components.climate import (
|
from homeassistant.components.climate import (
|
||||||
FAN_ON, FAN_OFF, SWING_OFF, SWING_BOTH, SWING_VERTICAL, SWING_HORIZONTAL,
|
FAN_ON, FAN_OFF, SWING_OFF, SWING_BOTH, SWING_VERTICAL, SWING_HORIZONTAL,
|
||||||
@ -101,21 +102,19 @@ class FeatureOnOff(MIoTServiceEntity, ClimateEntity):
|
|||||||
self._prop_on = None
|
self._prop_on = None
|
||||||
|
|
||||||
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
||||||
# properties
|
|
||||||
for prop in entity_data.props:
|
def _init_on_off(self, service_name: str, prop_name: str) -> None:
|
||||||
if prop.name == 'on':
|
"""Initialize the on_off feature."""
|
||||||
if (
|
for prop in self.entity_data.props:
|
||||||
# The "on" property of the "fan-control" service is not
|
if prop.name == prop_name and prop.service.name == service_name:
|
||||||
# the on/off feature of the entity.
|
if prop.format_ != bool:
|
||||||
prop.service.name == 'air-conditioner' or
|
_LOGGER.error('wrong format %s %s, %s', service_name,
|
||||||
prop.service.name == 'heater' or
|
prop_name, self.entity_id)
|
||||||
prop.service.name == 'thermostat' or
|
continue
|
||||||
prop.service.name == 'electric-blanket'):
|
self._attr_supported_features |= ClimateEntityFeature.TURN_ON
|
||||||
self._attr_supported_features |= (
|
self._attr_supported_features |= ClimateEntityFeature.TURN_OFF
|
||||||
ClimateEntityFeature.TURN_ON)
|
|
||||||
self._attr_supported_features |= (
|
|
||||||
ClimateEntityFeature.TURN_OFF)
|
|
||||||
self._prop_on = prop
|
self._prop_on = prop
|
||||||
|
break
|
||||||
|
|
||||||
async def async_turn_on(self) -> None:
|
async def async_turn_on(self) -> None:
|
||||||
"""Turn on."""
|
"""Turn on."""
|
||||||
@ -134,6 +133,7 @@ class FeatureTargetTemperature(MIoTServiceEntity, ClimateEntity):
|
|||||||
entity_data: MIoTEntityData) -> None:
|
entity_data: MIoTEntityData) -> None:
|
||||||
"""Initialize the feature class."""
|
"""Initialize the feature class."""
|
||||||
self._prop_target_temp = None
|
self._prop_target_temp = None
|
||||||
|
self._attr_temperature_unit = None
|
||||||
|
|
||||||
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
||||||
# properties
|
# properties
|
||||||
@ -151,6 +151,10 @@ class FeatureTargetTemperature(MIoTServiceEntity, ClimateEntity):
|
|||||||
self._attr_supported_features |= (
|
self._attr_supported_features |= (
|
||||||
ClimateEntityFeature.TARGET_TEMPERATURE)
|
ClimateEntityFeature.TARGET_TEMPERATURE)
|
||||||
self._prop_target_temp = prop
|
self._prop_target_temp = prop
|
||||||
|
break
|
||||||
|
# temperature_unit is required by the climate entity
|
||||||
|
if not self._attr_temperature_unit:
|
||||||
|
self._attr_temperature_unit = UnitOfTemperature.CELSIUS
|
||||||
|
|
||||||
async def async_set_temperature(self, **kwargs):
|
async def async_set_temperature(self, **kwargs):
|
||||||
"""Set the target temperature."""
|
"""Set the target temperature."""
|
||||||
@ -197,6 +201,7 @@ class FeaturePresetMode(MIoTServiceEntity, ClimateEntity):
|
|||||||
self._attr_supported_features |= (
|
self._attr_supported_features |= (
|
||||||
ClimateEntityFeature.PRESET_MODE)
|
ClimateEntityFeature.PRESET_MODE)
|
||||||
self._prop_mode = prop
|
self._prop_mode = prop
|
||||||
|
break
|
||||||
|
|
||||||
async def async_set_preset_mode(self, preset_mode: str) -> None:
|
async def async_set_preset_mode(self, preset_mode: str) -> None:
|
||||||
"""Set the preset mode."""
|
"""Set the preset mode."""
|
||||||
@ -365,6 +370,7 @@ class FeatureTemperature(MIoTServiceEntity, ClimateEntity):
|
|||||||
for prop in entity_data.props:
|
for prop in entity_data.props:
|
||||||
if prop.name == 'temperature':
|
if prop.name == 'temperature':
|
||||||
self._prop_env_temperature = prop
|
self._prop_env_temperature = prop
|
||||||
|
break
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def current_temperature(self) -> Optional[float]:
|
def current_temperature(self) -> Optional[float]:
|
||||||
@ -387,6 +393,7 @@ class FeatureHumidity(MIoTServiceEntity, ClimateEntity):
|
|||||||
for prop in entity_data.props:
|
for prop in entity_data.props:
|
||||||
if prop.name == 'relative-humidity':
|
if prop.name == 'relative-humidity':
|
||||||
self._prop_env_humidity = prop
|
self._prop_env_humidity = prop
|
||||||
|
break
|
||||||
|
|
||||||
@property
|
@property
|
||||||
def current_humidity(self) -> Optional[float]:
|
def current_humidity(self) -> Optional[float]:
|
||||||
@ -418,6 +425,7 @@ class FeatureTargetHumidity(MIoTServiceEntity, ClimateEntity):
|
|||||||
self._attr_supported_features |= (
|
self._attr_supported_features |= (
|
||||||
ClimateEntityFeature.TARGET_HUMIDITY)
|
ClimateEntityFeature.TARGET_HUMIDITY)
|
||||||
self._prop_target_humidity = prop
|
self._prop_target_humidity = prop
|
||||||
|
break
|
||||||
|
|
||||||
async def async_set_humidity(self, humidity):
|
async def async_set_humidity(self, humidity):
|
||||||
"""Set the target humidity."""
|
"""Set the target humidity."""
|
||||||
@ -447,6 +455,8 @@ class Heater(FeatureOnOff, FeatureTargetTemperature, FeatureTemperature,
|
|||||||
self._attr_icon = 'mdi:radiator'
|
self._attr_icon = 'mdi:radiator'
|
||||||
# hvac modes
|
# hvac modes
|
||||||
self._attr_hvac_modes = [HVACMode.HEAT, HVACMode.OFF]
|
self._attr_hvac_modes = [HVACMode.HEAT, HVACMode.OFF]
|
||||||
|
# on/off
|
||||||
|
self._init_on_off('heater', 'on')
|
||||||
# preset modes
|
# preset modes
|
||||||
self._init_preset_modes('heater', 'heat-level')
|
self._init_preset_modes('heater', 'heat-level')
|
||||||
|
|
||||||
@ -482,10 +492,12 @@ class AirConditioner(FeatureOnOff, FeatureTargetTemperature,
|
|||||||
|
|
||||||
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
super().__init__(miot_device=miot_device, entity_data=entity_data)
|
||||||
self._attr_icon = 'mdi:air-conditioner'
|
self._attr_icon = 'mdi:air-conditioner'
|
||||||
|
# on/off
|
||||||
|
self._init_on_off('air-conditioner', 'on')
|
||||||
# hvac modes
|
# hvac modes
|
||||||
self._attr_hvac_modes = None
|
self._attr_hvac_modes = None
|
||||||
for prop in entity_data.props:
|
for prop in entity_data.props:
|
||||||
if prop.name == 'mode':
|
if prop.name == 'mode' and prop.service.name == 'air-conditioner':
|
||||||
if not prop.value_list:
|
if not prop.value_list:
|
||||||
_LOGGER.error('invalid mode value_list, %s', self.entity_id)
|
_LOGGER.error('invalid mode value_list, %s', self.entity_id)
|
||||||
continue
|
continue
|
||||||
@ -620,22 +632,17 @@ class PtcBathHeater(FeatureTargetTemperature, FeatureTemperature,
|
|||||||
self._attr_icon = 'mdi:hvac'
|
self._attr_icon = 'mdi:hvac'
|
||||||
# hvac modes
|
# hvac modes
|
||||||
for prop in entity_data.props:
|
for prop in entity_data.props:
|
||||||
if prop.name == 'mode':
|
if prop.name == 'mode' and prop.service.name == 'ptc-bath-heater':
|
||||||
if not prop.value_list:
|
if not prop.value_list:
|
||||||
_LOGGER.error('invalid mode value_list, %s', self.entity_id)
|
_LOGGER.error('invalid mode value_list, %s', self.entity_id)
|
||||||
continue
|
continue
|
||||||
self._hvac_mode_map = {}
|
self._hvac_mode_map = {}
|
||||||
for item in prop.value_list.items:
|
for item in prop.value_list.items:
|
||||||
if item.name in {'off', 'idle'}:
|
if item.name in {'off', 'idle'}:
|
||||||
if (HVACMode.OFF
|
|
||||||
not in list(self._hvac_mode_map.values())):
|
|
||||||
self._hvac_mode_map[item.value] = HVACMode.OFF
|
self._hvac_mode_map[item.value] = HVACMode.OFF
|
||||||
elif (HVACMode.AUTO
|
break
|
||||||
not in list(self._hvac_mode_map.values())):
|
if self._hvac_mode_map:
|
||||||
self._hvac_mode_map[item.value] = HVACMode.AUTO
|
self._attr_hvac_modes = [HVACMode.AUTO, HVACMode.OFF]
|
||||||
self._attr_hvac_modes = list(self._hvac_mode_map.values())
|
|
||||||
if HVACMode.OFF in self._attr_hvac_modes:
|
|
||||||
self._prop_mode = prop
|
|
||||||
else:
|
else:
|
||||||
_LOGGER.error('no idle mode, %s', self.entity_id)
|
_LOGGER.error('no idle mode, %s', self.entity_id)
|
||||||
# preset modes
|
# preset modes
|
||||||
@ -643,7 +650,7 @@ class PtcBathHeater(FeatureTargetTemperature, FeatureTemperature,
|
|||||||
|
|
||||||
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
|
async def async_set_hvac_mode(self, hvac_mode: HVACMode) -> None:
|
||||||
"""Set the target hvac mode."""
|
"""Set the target hvac mode."""
|
||||||
if self._prop_mode is None:
|
if self._prop_mode is None or hvac_mode != HVACMode.OFF:
|
||||||
return
|
return
|
||||||
mode_value = self.get_map_key(map_=self._hvac_mode_map, value=hvac_mode)
|
mode_value = self.get_map_key(map_=self._hvac_mode_map, value=hvac_mode)
|
||||||
if mode_value is None or not await self.set_property_async(
|
if mode_value is None or not await self.set_property_async(
|
||||||
@ -656,13 +663,12 @@ class PtcBathHeater(FeatureTargetTemperature, FeatureTemperature,
|
|||||||
"""The current hvac mode."""
|
"""The current hvac mode."""
|
||||||
if self._prop_mode is None:
|
if self._prop_mode is None:
|
||||||
return None
|
return None
|
||||||
mode_value = self.get_map_value(
|
current_mode = self.get_prop_value(prop=self._prop_mode)
|
||||||
map_=self._hvac_mode_map,
|
if current_mode is None:
|
||||||
key=self.get_prop_value(prop=self._prop_mode))
|
return None
|
||||||
if mode_value == HVACMode.OFF or mode_value is None:
|
mode_value = self.get_map_value(map_=self._hvac_mode_map,
|
||||||
return mode_value
|
key=current_mode)
|
||||||
return HVACMode.AUTO if (HVACMode.AUTO
|
return HVACMode.OFF if mode_value == HVACMode.OFF else HVACMode.AUTO
|
||||||
in self._attr_hvac_modes) else None
|
|
||||||
|
|
||||||
|
|
||||||
class Thermostat(FeatureOnOff, FeatureTargetTemperature, FeatureTemperature,
|
class Thermostat(FeatureOnOff, FeatureTargetTemperature, FeatureTemperature,
|
||||||
@ -677,6 +683,8 @@ class Thermostat(FeatureOnOff, FeatureTargetTemperature, FeatureTemperature,
|
|||||||
self._attr_icon = 'mdi:thermostat'
|
self._attr_icon = 'mdi:thermostat'
|
||||||
# hvac modes
|
# hvac modes
|
||||||
self._attr_hvac_modes = [HVACMode.AUTO, HVACMode.OFF]
|
self._attr_hvac_modes = [HVACMode.AUTO, HVACMode.OFF]
|
||||||
|
# on/off
|
||||||
|
self._init_on_off('thermostat', 'on')
|
||||||
# preset modes
|
# preset modes
|
||||||
self._init_preset_modes('thermostat', 'mode')
|
self._init_preset_modes('thermostat', 'mode')
|
||||||
|
|
||||||
@ -705,6 +713,8 @@ class ElectricBlanket(FeatureOnOff, FeatureTargetTemperature,
|
|||||||
self._attr_icon = 'mdi:rug'
|
self._attr_icon = 'mdi:rug'
|
||||||
# hvac modes
|
# hvac modes
|
||||||
self._attr_hvac_modes = [HVACMode.HEAT, HVACMode.OFF]
|
self._attr_hvac_modes = [HVACMode.HEAT, HVACMode.OFF]
|
||||||
|
# on/off
|
||||||
|
self._init_on_off('electric-blanket', 'on')
|
||||||
# preset modes
|
# preset modes
|
||||||
self._init_preset_modes('electric-blanket', 'mode')
|
self._init_preset_modes('electric-blanket', 'mode')
|
||||||
|
|
||||||
|
@ -25,7 +25,7 @@
|
|||||||
"cryptography",
|
"cryptography",
|
||||||
"psutil"
|
"psutil"
|
||||||
],
|
],
|
||||||
"version": "v0.2.2",
|
"version": "v0.2.3",
|
||||||
"zeroconf": [
|
"zeroconf": [
|
||||||
"_miot-central._tcp.local."
|
"_miot-central._tcp.local."
|
||||||
]
|
]
|
||||||
|
@ -168,5 +168,20 @@
|
|||||||
"service:016:action:001": "中键确认",
|
"service:016:action:001": "中键确认",
|
||||||
"service:017:action:001": "右键确认"
|
"service:017:action:001": "右键确认"
|
||||||
}
|
}
|
||||||
|
},
|
||||||
|
"urn:miot-spec-v2:device:bath-heater:0000A028:yeelink-v10": {
|
||||||
|
"en": {
|
||||||
|
"service:003:property:001:valuelist:000": "Idle",
|
||||||
|
"service:003:property:001:valuelist:001": "Dry"
|
||||||
|
}
|
||||||
|
},
|
||||||
|
"urn:miot-spec-v2:device:plant-monitor:0000A030:hhcc-v1": {
|
||||||
|
"en": {
|
||||||
|
"service:002:property:001": "Soil Moisture"
|
||||||
|
},
|
||||||
|
"zh-Hans": {
|
||||||
|
"service:002:property:001": "土壤湿度",
|
||||||
|
"service:002:property:003": "光照强度"
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
@ -76,3 +76,56 @@ urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:2: urn:miot-spec-v2:d
|
|||||||
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:3: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:3: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
||||||
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:4: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:4: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
||||||
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:5: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:5: urn:miot-spec-v2:device:air-conditioner:0000A004:xiaomi-m9:6
|
||||||
|
urn:miot-spec-v2:device:airer:0000A00D:mrbond-m33a:1:
|
||||||
|
prop.2.3:
|
||||||
|
name: current-position-a
|
||||||
|
prop.2.11:
|
||||||
|
name: current-position-b
|
||||||
|
urn:miot-spec-v2:device:thermostat:0000A031:suittc-wk168:1:
|
||||||
|
prop.2.3:
|
||||||
|
value-list:
|
||||||
|
- value: 1
|
||||||
|
description: '1'
|
||||||
|
- value: 2
|
||||||
|
description: '2'
|
||||||
|
- value: 3
|
||||||
|
description: '3'
|
||||||
|
- value: 4
|
||||||
|
description: '4'
|
||||||
|
- value: 5
|
||||||
|
description: '5'
|
||||||
|
- value: 6
|
||||||
|
description: '6'
|
||||||
|
- value: 7
|
||||||
|
description: '7'
|
||||||
|
- value: 8
|
||||||
|
description: '8'
|
||||||
|
- value: 9
|
||||||
|
description: '9'
|
||||||
|
- value: 10
|
||||||
|
description: '10'
|
||||||
|
- value: 11
|
||||||
|
description: '11'
|
||||||
|
- value: 12
|
||||||
|
description: '12'
|
||||||
|
- value: 13
|
||||||
|
description: '13'
|
||||||
|
- value: 14
|
||||||
|
description: '14'
|
||||||
|
- value: 15
|
||||||
|
description: '15'
|
||||||
|
- value: 16
|
||||||
|
description: '16'
|
||||||
|
urn:miot-spec-v2:device:outlet:0000A002:chuangmi-212a01:3:
|
||||||
|
prop.5.1:
|
||||||
|
expr: round(src_value*6/1000000, 3)
|
||||||
|
urn:miot-spec-v2:device:outlet:0000A002:chuangmi-212a01:1: urn:miot-spec-v2:device:outlet:0000A002:chuangmi-212a01:3
|
||||||
|
urn:miot-spec-v2:device:outlet:0000A002:chuangmi-212a01:2: urn:miot-spec-v2:device:outlet:0000A002:chuangmi-212a01:3
|
||||||
|
urn:miot-spec-v2:device:plant-monitor:0000A030:hhcc-v1:1:
|
||||||
|
prop.2.1:
|
||||||
|
name: soil-moisture
|
||||||
|
icon: mdi:watering-can
|
||||||
|
prop.2.2:
|
||||||
|
name: soil-ec
|
||||||
|
icon: mdi:sprout-outline
|
||||||
|
unit: μS/cm
|
||||||
|
@ -560,12 +560,6 @@ SPEC_PROP_TRANS_MAP: dict = {
|
|||||||
'entity': 'sensor',
|
'entity': 'sensor',
|
||||||
'state_class': SensorStateClass.MEASUREMENT,
|
'state_class': SensorStateClass.MEASUREMENT,
|
||||||
'unit_of_measurement': UnitOfPower.WATT
|
'unit_of_measurement': UnitOfPower.WATT
|
||||||
},
|
|
||||||
'total-battery': {
|
|
||||||
'device_class': SensorDeviceClass.ENERGY,
|
|
||||||
'entity': 'sensor',
|
|
||||||
'state_class': SensorStateClass.TOTAL_INCREASING,
|
|
||||||
'unit_of_measurement': UnitOfEnergy.KILO_WATT_HOUR
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
Loading…